SL-UPS-INTERNET550U

Uninterruptable Power Supply - 550VA 300W Standby - 10 NEMA 5-15R Outlets, 120V, 50/60 Hz, USB, 5-15P Plug, Desktop/Wall Mount

Compact desktop UPS with silent alarm provides battery backup support for your home/office network system or digital signage components.
  • Protects equipment against blackouts, brownouts, overvoltages, surges and line noise
  • Keeps AC power running during blackouts to allow time for file saves and safe shutdown
  • 10 NEMA 5-15R outlets power and protect PC, home theater or digital signage equipment
  • Home-friendly alarm remains silent in backup mode, sounding only when imperative
  • High >98% efficiency with low BTU ratings saves electricity and lowers your energy costs
INPUT
Input Phase Single-Phase
Rated input current (Maximum Load) 6A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 7A
UPS Input Cord Length (ft.) 5
Recommended Electrical Service 15A 120V
OUTPUT
Output Capacity (VA) 550
Output Capacity (kVA) 0.55
Output Capacity (Watts) 300
Output Capacity (kW) 0.3
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) 120V (±20%)
Output Voltage Regulation (Battery Mode) 120V (±10%)
UPS Output Receptacles (Surge Suppression Only) 5 UPS outlets, 5 surge-only outlets
Output AC Waveform (AC Mode) Pure sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (10) 5-15R
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)   1.2 min. (300W)
Runtime Half Load (min.)   5 min. (150W)
DC System Voltage (VDC) 12
Battery Recharge Rate (Included Batteries) 6.5 hours (10% to 90%)
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge IMPORTANT BATTERY REPLACEMENT INFORMATION > If your INTERNET550U has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your INTERNET550U UPS does have a battery replacement door and the original battery inside has a rating of 12V 3.6AH, please order Tripp Lite replacement battery Model Number  RBC36H 
USER INTERFACE, ALERTS & CONTROLS
Switches Switch controls power off/on status
Audible Alarm UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
LED Indicators 1 Status LED reports operating mode and fault status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 316
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL or Ethernet
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Desktop
Installation Form Factors Supported with Included Accessories Tower; Ultra-compact desktop; Wallmount
Primary UPS Depth (mm) 185
Primary UPS Height (mm) 105
Primary UPS Width (mm) 110
Shipping Dimensions (hwd / in.) 7.36 x 5.67 x 10.86
Shipping Weight (lbs.) 4.92
UPS Housing Material ABS
UPS Power Module Dimensions (hwd, in.) 4.13 x 4.33 x 7.28
UPS Power Module Weight (kg) 1.80
UPS Power Module Weight (lbs.) 3.96
Unit Dimensions (hwd / in.) 4.130 x 4.330 x 7.280
Unit Weight (lbs.) 4.920
ENVIRONMENTAL
Operating Temperature Range 32° to 104°F (0° to 40°C)
Storage Temperature Range 5° to 113°F (-15° to 45°C )
Relative Humidity 0 to 90%, non-condensing
AC Mode BTU / Hr. (Full Load)   13.1
AC Mode Efficiency Rating (100% Load) >98%
Operating Elevation (ft.) Up to 10,000 ft.
Operating Elevation (m) Up to 3000m
COMMUNICATIONS
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications Cable USB interface cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management not supported
Communications Interface USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   6 milliseconds typical (10 milliseconds max)
Low Voltage Transfer to Battery Power (Setpoint) 95
High Voltage Transfer to Battery Power (Setpoint) 145
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS
APPLICATIONS
UPS Applications Computer/Peripherals; Retail/Point of Sale; Hospitality
STANDARDS & COMPLIANCE
Product Certifications CAN/CSA-C22.2 No. 107.3 (Canada); NOM (Mexico); RETIE (Colombia); UL 1778
Product Compliance FCC Part 15 Class B (USA); FCC Part 68; RoHS