8516 This item is no longer available.
Complete RS-232 Strain Gage/Load Cell DAQ System; High Resolution 16-Bit A/D with front end amplification, Provides 0 to 10VDC Excitation (40mA) - Includes WINview CP Plus 2012: Ready-to-Run Collection, Graphing & Logging Software, Fully Compatible wit...
- Complete RS-232 Data Acquisition System
- Ideal for Strain Gage, Load Cell, LVDT Inputs and more
- 16-Bit A/D Converter
- Expandable to 8 or more Inputs with optional 8018s
- High Precision Excitation settable from 0-10VDC (40mA available)
- Amplification for low level strain gage voltages
- 4 Digital Outputs (Not Supported by WINview CP)
- 1 Digital Input (Not Supported by WINview CP)
- Ready-to-Run System Includes:
- 8520 for direct RS-232
- 8016 (prewired)
- RS-232 Cable
- Power Supply
- WINview CP Plus 2012 Ready-to-Run Software - Supports Analog Inputs Only
- Includes Free CD with user Manuals, Visual Basic Examples, Drivers for DASYLab, Compatible with TestPoint, Software Utilities, and WINview CP, LINUX driver available upon request
- WINview CP 2012 is compatible with Windows XP SP3, Windows Vista, Windows 7, Windows 8, and Windows 10 32-bit and 64-bit Operating Systems
 
Hardware Specifications:
- 
      - 
              Analog Input:
              - Input Channels:2
- Input type : +/-15mV, +/-50mV, +/-100mV, +/-1V, +/-2.5V, +/-20mA
- Max. Sampling rate of Module: 10 Samples/Second (0.10 seconds between samples)
- Bandwidth: 5.24Hz
- Accuracy: ±0.05% FSR
- Zero Drift: ±0.5µV/ °C
- Span Drift: 25ppm/°C
- Common Mode Rejection @ 50/60Hz: 150dB
- Normal Mode Rejection @ 50/60Hz: 100dB
- Input Impedance: 20M Ohms
- Intra-Module Isolation: 3000VDC
 
- 
              Excitation Voltage Output
              - Output Channels: 1
- Output Range: 0 to +10V
- Max Output Load: 40mA
- Accuracy: ±0.05% of FSR
- Drift: ±50ppm/ °C
- Output Impedance: 12 Ohms
- Isolation: 3000V DC
 
- 
              Digital Input:
              - Channels: 1
- Logic Level 0: +1V max
- Logic Level 1: +3.5 to 30V
- Max Input Frequency: 50Hz
- Min. Pulse Width: 1mS
 
- 
              Digital Output:
              - Channels: 4
- Output Type: Open Collector to 30V
- Output Load: Sink 30mA max
- Power Dissipation: 30mW
 
- 
              Interface:
              - RS-485
- Format: N,8,1
- Baud Rate: 1200 ~ 115200 bps
- Connections: Terminal blocks (accepts 16-22 AWG wires)
 
- 
              LED Display:
              - 1 LED as Power/Communication Indicator
 
- 
              Power:
              - Input Voltage Range: +10 to +30V DC
- Power Consumption: 2.4W
 
- 
              Physical & Environmental:
              - Operating Temperature: -13 to 167°F (-25 to 75°C)
- Storage Temperature: -40 to 176°F (-40 to 80°C)
- Dimensions: 4.8 x 2.8 x 1.3 in (12.3 x 7.2 x 3.3 cm)
 
 
- 
              Analog Input:
              
Software Specifications:
- 
   - 
         Hardware Requirements:
         - One 8000 Series Analog Input Module Connected via USB or RS232
- 512MB RAM
- 6MB Hard Disk Space (For WINview CP 2012 Only - Additional Space Required for Data Storage and/or .NET Framework)
 
- 
         Software Requirements
         - Windows XP (Service Pack 3), Windows Vista or Windows 7 (32-bit or 64-bit)
- Microsoft .NET Framework Version 4.0 or Higher
- 1024 x 768 Resolution or Higher
- Requires Administrator User Privileges
 
- 
         General Software Specifications:
         - 
               Maximum Number of Inputs:
               - Number and Type of Channels Determined by Module Used
 
- 
               Supported Signal Types:
               - 
                     All Analog Input Types:
                     - Volts, mV, mA, Thermocouple, RTD, Strain Gauge, etc.
 
 
- 
                     All Analog Input Types:
                     
- 
               Ease of Use:
               - Very Easy, No Learning Curve, No Programming, No Manual Needed
 
- 
               Speed of Acquisition:
               - Maximum: 10 Hz (May be Limited by Hardware)
- Minimum: None
 
- 
               Duration of Acquisition:
               - Finite (Specify Number of Points to Collect)
- Continuous (Collects Until Stopped by User)
 
- 
               Data Storage:
               - Stream Data to Disk as ASCII Text (Tab Delimited)
- Stream Data to Disk as ASCII Text with Time/Date Stamp Options (Tab Delimited)
- Easily Import into Microsoft Excel
 
- 
               Settings Retrieval
               - All User Settings May Be Saved to a File for Later Use
- Selectable Auto-Load of Specified Settings File
 
- 
               Math Formulas Per Channel:
               - Yes
- Supports the Following Math Functions: +, -, *, /, ( ), sin, cos, tan, ^, ln, sqr, exp
 
- 
               Real-Time Display:
               - Yes, Selectable Graphing Options
 
 
- 
               Maximum Number of Inputs:
               
- 
         Graph Specifications:
         - 
               Display:
               - Time vs. Y
- Multiple Channels per Graph
- Digital Readout of Each Channel
- Strip-Chart Mode
- User Selectable Graph Type (Line, Bar, Pie, etc.)
 
 
- 
               Display:
               
- 
        - 
              X-Axis:
              - Samples, Seconds, Minutes, Hours, Days
- Supports Auto-Scaling
 
- 
              Y-Axis:
              - User-Defineable
- Supports Auto-Scaling
 
- 
              Graph Functions:
              - Print Graph Image
- Save Graph Image
- Zoom Graph Image
- Copy Graph Image to Clipboard
 
- 
              Trigger Type:
              - Software Push Button
 
 
- 
              X-Axis:
              
 
- 
         Hardware Requirements:
         
 
 
 
         
        